查找地点
有关时间、上门服务和预约查找地点
有关时间、上门服务和预约Pertinent medical findings must accompany test request form. For formalin fixed paraffin embedded blocks or slides, test number will be updated to Microarray-Products of Conception (POC) Reveal® FFPE [511997]. If <8 mg nonfixed tissue is received, sample will be assessed to run on the Oncoscan Microarray platform, and test number adjusted as necessary and client notified.
If prior NIPT studies have been performed, include copy of the report.
12 - 18 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
For more information, please view the literature below.
SNP Microarray Prenatal POC Clinical Questionnaire
Preferred nonfixed tissue or products of conception (POC)/placental villus biopsy
>8 mg tissue
The transport tube (a sterile specimen container with transport medium) is available from Labcorp. Please call customer service at 800-345-4363. (Do not use isotonic saline as a transport medium or urine containers for shipping.) Specialized kits are now available for POC microarray testing. To order, please contact your local Labcorp representative (PeopleSoft No. 89063, catalogue item ID No. 39025G).
Aseptically obtain a small piece of fetal tissue that does not appear necrotic. If specimen is a POC, placental villi or membranes may be the only fetal-derived tissue available, and an effort should be made to submit these tissues rather than maternal decidua.
Maintain specimen at room temperature.
Quantity not sufficient for analysis; necrotic tissue submitted
This test will detect chromosomal imbalance that could be associated with developmental delay/congenital anomalies. It provides possible detection of uniparental disomy of any chromosome, the percent and location of homozygosity, including the degree of identity by descent. It will also allow the detection of complete or partial molar pregnancies.
Unable to determine genotypes on some formalin-fixed tissue (blocks/slides), allowing only genomic dosage to be determined. This SNP assay does not detect balanced rearrangements, low-level mosaicism (<10%), marker chromosomes that only contain heterochromatin or tetraploidy.
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
SNP microarray analysis is performed using the Cytoscan® HD Accel platform, which uses 743,130 SNP probes and 2,029,441 NPCN probes with a median spacing of 0.818 kb.
The microarray will detect DNA copy-number changes at a threshold >1 Mb for deletions, >2 Mb for duplications.
Order Code | Order Code Name | Order Loinc | Result Code | Result Code Name | UofM | Result LOINC |
---|---|---|---|---|---|---|
510110 | POC/Tissue Microarray | 96984-0 | 510112 | Specimen Type | 31208-2 | |
510110 | POC/Tissue Microarray | 96984-0 | 510113 | # of Genotyping Targets | N/A | |
510110 | POC/Tissue Microarray | 96984-0 | 510114 | Array Type | 96984-0 | |
510110 | POC/Tissue Microarray | 96984-0 | 510116 | Diagnosis | 48000-4 | |
510110 | POC/Tissue Microarray | 96984-0 | 510117 | Interpretation | 62365-2 | |
510110 | POC/Tissue Microarray | 96984-0 | 510118 | Director Review: | 48672-0 | |
510110 | POC/Tissue Microarray | 96984-0 | 512123 | 51967-8 |
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf