查找地点
有关时间、上门服务和预约查找地点
有关时间、上门服务和预约Please provide a copy of the pathology report. Direct any questions regarding this test to customer service at 800-345-4363. BRAF testing will be delayed if the pathology report is not received.
5 - 7 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
Solid tumor: Formalin-fixed, paraffin-embedded (FFPE) tissue blocks or slides; thyroid fine needle aspirate (FNA). Leukemia: whole blood or bone marrow
FFPE tissue block or four unstained slides and one matching H&E-stained slide at 5 μM; 5 to 10 mL FNA in CytoLyt container; 3 to 5 mL whole blood, 1 to 2 mL bone marrow
Two unstained slides and one matching H&E-stained slide at 5 μM. Sample with >4mm2 and greater than or equal to 50% tumor content are preferred; 5 mL FNA; 3 mL blood, 1 mL bone marrow
FFPE tissue block or slides, lavender-top (EDTA) tube, green-top (sodium heparin) tube, yellow-top (ACD-A) tube, FNA CytoLyt container, tan-top (K2-EDTA) tube or pink-top (K2-EDTA) tube
Maintain specimen at room temperature. If specimen is to be stored prior to shipment, store at 2°C to 8°C. Store FFPE block or slides, FNA in CytoLyt container at room temperature.
Tumor block containing no tumor; broken or stained slides; specimen does not meet collection criteria; frozen whole blood, marrow, or cell pellet; leaking tube; clotted blood or marrow; grossly hemolyzed specimen or otherwise visibly degraded; contamination by another specimen; specimens containing suspicious foreign material
BRAF is an important member of the mitogen-activated protein kinase (MAPK) pathway that influences cell proliferation. This test will detect all V600 mutations of the BRAF oncogene frequently found in human cancers, such as melanoma, colorectal cancer, gastric cancer, lung cancer, ovarian cancer, thyroid cancer, and hairy cell leukemia, allowing the determination of drug response, aiding the diagnosis and providing prognosis information. More than 90% of mutations are the V600E (c1799T>A) mutation, but other V600 mutations have been reported.
This test can distinquish the following BRAF V600 mutations: V600E, V600E2, V600K, V600D, V600R, V600A, V600G, V600M, V600L.
BRAF is an important member of the mitogen-activated protein kinase (MAPK) pathway that influences cell proliferation. This test will detect all V600 mutations of the BRAF oncogene frequently found in human cancers, such as melanoma, colorectal cancer, lung cancer, ovarian cancer, thyroid cancer, and hairy cell leukemia, allowing the determination of drug response, aiding the diagnosis and providing prognosis information. More than 90% of mutations are the V600E (c1799T>A) mutation, but other V600 mutations have been reported. This test can distinquish the following BRAF V600 mutations: V600E, V600E2, V600K, V600D, V600R, V600A, V600G, V600M, V600L. |
BRAF is an important member of the mitogen-activated protein kinase (MAPK) pathway that influences cell proliferation. This test will detect all V600 mutations of the BRAF oncogene frequently found in human cancers, such as melanoma, colorectal cancer, gastric cancer, lung cancer, ovarian cancer, thyroid cancer, and hairy cell leukemia, allowing the determination of drug response, aiding the diagnosis and providing prognosis information. More than 90% of mutations are the V600E (c1799T>A) mutation, but other V600 mutations have been reported. This test can distinquish the following BRAF V600 mutations: V600E, V600E2, V600K, V600D, V600R, V600A, V600G, V600M, V600L. |
This assay is able to detect 5% mutation in a background of wild-type DNA.
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
SNaPshot Multiplex PCR (primer extension-based method)
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf