查找地点
有关时间、上门服务和预约查找地点
有关时间、上门服务和预约Co-administration of Lorazepam can potentially cause a falsely lower Clonazepam result in this method.
2 - 4 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
Serum or plasma
4 mL
1.1 mL
Red-top tube, lavender-top (EDTA) tube, or green-top (heparin) tube. Do not use a gel-barrier tube. The use of gel-barrier tubes is not recommended due to slow absorption of the drug by the gel. Depending on the specimen volume and storage time, the decrease in drug level due to absorption may be clinically significant.
Transfer separated serum or plasma to a plastic transport tube. Collect specimen immediately prior to next dose unless specified otherwise.
Refrigerate.
Temperature | Period |
---|---|
Room temperature | 14 days |
Refrigerated | 14 days |
Frozen | 14 days |
Gel-barrier tube
Evaluate toxicity; monitor therapeutic levels
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
Liquid chromatography/tandem mass spectrometry (LC/MS-MS)
Therapeutic: 20−70 ng/mL
The drug is used in the treatment of petit mal variant (Lennox-Gastaut), akinetic seizures and myoclonic seizures. Serum peak levels occur approximately two hours after oral administration. The apparent half-life after a single oral dose is 20 to 40 hours. Active metabolites have longer half-lives than the parent drug. Half-lives are increased in the elderly. Therapeutic effect is not well correlated with serum levels. Effect of CNS depressants may be augmented by concomitant use of this agent. This drug is used as an anticonvulsant. It is useful in reducing tardive dyskinesia.1
Order Code | Order Code Name | Order Loinc | Result Code | Result Code Name | UofM | Result LOINC |
---|---|---|---|---|---|---|
071712 | Clonazepam (Klonopin(R)),Serum | 3494-2 | 071712 | Clonazepam (Klonopin(R)),Serum | ng/mL | 3494-2 |
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf