查找地点
有关时间、上门服务和预约查找地点
有关时间、上门服务和预约2 - 3 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
For more information, please view the literature below.
Procedures for Hemostasis and Thrombosis: A Clinical Test Compendium
Plasma, frozen
1 mL
Blue-top (sodium citrate) tubes
Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Freeze. Stable refrigerated for four hours.
Hemolysis; clotted specimen; specimen contaminated with heparin (ie, drawn with blood gases)
Monitor prophylactic fondaparinux levels in patient plasma6
Severe hemolysis, bilirubinemia, and lipemia may interfere with this assay. Improper sample preparation or handling may affect assay results or sample stability, especially after freezing. Release of platelet factor 4 resulting from inadequate removal of platelets or platelet activation of the sample may reduce the measured heparin concentration. A therapeutic range has not been established.
Chromogenic
Order Code | Order Code Name | Order Loinc | Result Code | Result Code Name | UofM | Result LOINC |
---|---|---|---|---|---|---|
500465 | Anti-Xa-Fondaparinux | 500466 | Anti-Xa-Fondaparinux | mg/L | 74217-1 |
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf